Electricity gives no warning. You cannot see it, hear it or smell it, and one contact can stop your heart. Most electrical injuries on site come from damaged leads, wet conditions and people doing electrical work they are not qualified for.

Takes about 7 minutes, plus a 5-question quiz.

Key points to read out

  1. Only licensed or qualified electricians do electrical work. Do not wire, rewire or open up anything yourself.
  2. Use GFCIs on all 120-volt, 15, 20 and 30 amp temporary receptacles, or a written assured equipment grounding conductor program run by a competent person with recorded tests.
  3. Leads and tools on construction sites are inspected and tested on a regular schedule. Out of date means do not use.
  4. Treat every wire and circuit as live until it has been isolated and proved dead by a qualified person.
  5. Check leads and tools before use. Cut, crushed or taped cables get tagged out, not repaired with tape.
  6. Keep electrical gear out of water and away from wet ground. Do not handle plugs with wet hands.
  7. Run leads overhead or along walls on hooks, not through water, doorways or vehicle routes where they get crushed.
  8. Use non-conductive ladders near anything electrical. Metal ladders and live wires do not mix.
  9. Before cutting or drilling into walls, floors or ceilings, check for hidden cables with a detector and drawings.
  10. Look up before you set up. Scaffolds, ladders, long materials and plant must stay well clear of overhead lines and any service cable to the building.
  11. Never use a damaged power board, double adaptor or household lead on site.
  12. Know where the electrical panel is so power can be cut fast in an emergency.
  13. If someone gets a shock: do not touch them, switch off the power, call 911 and start CPR if needed.

Questions to ask the crew

  1. Where is the main electrical panel for this site?
  2. What do you do with a damaged lead?
  3. What would you do if you saw someone stuck to a live tool?
  4. How do we check for cables before cutting into a wall?
  5. Are there any overhead or service lines near our scaffold, ladders or plant today?

Reference: 29 CFR 1926 Subpart K (Electrical)

How to run this talk

  • Hold the talk next to the site switchboard or panel so everyone knows where to cut the power.
  • Bring one good lead and one damaged lead (tagged out) and ask the crew to find the faults.
  • Test an RCD or GFCI in front of the crew using its test button.
  • Walk the site and look up for overhead and service lines near scaffold, ladders and plant.
  • Finish by asking who has a tool or lead that is out of date, then record the talk on the sign-in sheet.

Electrical Safety on Site quiz

Ask these after the talk. Answers are underneath each question.

  1. Before plugging a power tool in on site, what protection must the supply have?

    1. None if the tool is new
    2. A GFCI, or a written assured equipment grounding conductor program
    3. A double adaptor with a fuse

    Answer: B. OSHA 1926.404(b)(1) requires GFCIs or an assured grounding program on construction sites.

  2. You find a lead with a cut in the outer sheath. What do you do?

    1. Wrap it in electrical tape
    2. Tag it out and take it out of use
    3. Use it only in dry areas

    Answer: B. Tape hides damage and does not restore the insulation, so damaged leads come out of service until repaired or replaced.

  3. Someone is stuck to a live tool and cannot let go. What do you do first?

    1. Grab them and pull them off
    2. Switch off the power at the source without touching them
    3. Throw water on them
    4. Pull the lead out by the cable while holding them

    Answer: B. Touching them puts the current through you too, so cut the power first, then call 911 and start CPR if needed.

  4. What should you assume about a wire or circuit you have not had isolated and proved dead?

    1. It is dead if the light switch is off
    2. It is live
    3. It is dead if it is painted over

    Answer: B. Only a qualified person can isolate and prove a circuit dead, so until then you treat it as live.

  5. Which ladder should you use near electrical work?

    1. Aluminium, because it is lighter
    2. Non-conductive fiberglass
    3. Any ladder if you wear gloves

    Answer: B. Metal ladders conduct electricity, so a fiberglass ladder removes one path to earth through your body.

Questions about electrical safety on site

Does OSHA require power tools to be tested and tagged?

OSHA has no general test and tag rule where GFCIs protect the circuits, but tools and cords must be kept in safe condition. Sites using an assured equipment grounding conductor program instead must visually inspect cords and tools before each day's use and test them before first use, after repair or damage, and at least every 3 months, with records kept (1926.404(b)(1)(iii)).

What is a GFCI and when is it required on a construction site?

A ground fault circuit interrupter cuts power when it detects current leaking to ground, such as through a person. OSHA requires GFCIs on all 120 volt, single phase, 15, 20 and 30 amp receptacles on construction sites that are not part of the permanent wiring, unless an assured equipment grounding conductor program is in place (1926.404(b)(1)).

What should you do if someone gets an electric shock?

Do not touch them while they could still be in contact with the power. Switch the power off at the source, call 911, and start CPR if they are not breathing normally; use an AED if there is one.

Who is allowed to do electrical work on a building site?